TECHNOLOGY REQUIREMENTS:
1、Color  Color is generally white. It may be agreed upon between the purchaser and the seller.
2、Length  Pipe lengths are supplied 4m, 6m. It may be agreed upon between the purchaser and the seller.
3、Pipe standard: Bosoar standard Q/BSA CP 02.1-2000(neq.GB/T5836.1-1992 Unplasticized polyvinyl chloride pipe for drainage in building). Fittings standard: GB/T5836.2-1992 Unplasticized polyvinyl chloride pipe for drainage in building.
4、Physical mechanics performance(see table1 and 2)

ITEM TECHNICAL INDEX
Vicat softening temperature, ℃ ≥79℃
Longitudinal reversion, % ≤5%
Tensile yield strength, Mpa ≥40
Flatting test No damage
Dropping impact resistance test(0℃)TIR ≤10%

Table2 fitting physical mechanics performance
ITEM TECHNICAL INDEX
Vicat softening temperature, ℃ ≥70℃
Oven test qualification
Dropping test No damage

Building drainage PVC-U pipe standard: Bosoar Standard Q/BSA CP 02.1-2000(neq. GB/T5836.1-1992) UNIT:mm

  • Normal outside diameter
  • 125
  • Average outside diameter
  • +0.40
  • type A
  • Normal thickness:- ; thickness tolerance:-
  • type B
  • Normal thickness: 3.2 ; thickness tolerance:+0.60